Cart 0

Double Beam UV VIS Spectrophotometer TRDUV-604 is a double-beam optical system with blazed holographic gratings. It has a sophisticated power protection system, a wavelength range of 190 to 1100 nm, a bandwidth of 2 nm, and an accuracy of 0.3 nm. it performs admirably in qualitative testing with a photometric display range of 0.0–200.0 % T, -0.301 to 4.000 A, 0.000 to 9999 C, and an accuracy of 0.3 % T (0 to 100 % T), 0.002A (0 to 0.5A), and 0.004A, (0.5A to 1A). It comes with a USB interface.

$1,833.00

Qty:

Specifications
Monochromatic type Czerny turner
Focal length 160 mm
Wavelength Range 190 to 1100nm
Band Width 2 nm
Wavelength Accuracy ±0.3 nm
Wavelength Repeatability ≤0.01 nm
Photometric Display Range 0.0 to 200 .0% T, -0.301 to 4.000 A, 0.000 to 9999 C
Photometric Accuracy ±0.3% T(0 to 100%T), ±0.002A(0 to 0.5A), ±0.004A(0.5A to 1A)
Photometric Repeatability 0.15% T(0 to 100%T), ±0.001A(0 to 0.5A) / ±0.002A(0.5A to 1A)
Photometric Mode T,A,C,E
Stray Light ≤0.03% τ (220nm NaI, 360nm NaNO2)
Stability 0.0005A/h@500 nm
Detector Import Silicon Photodiode
Scanning speed Fast-medium-slow
Power Requirement AC220V±22 50Hz±1Hz,200W
Baseline Flatness ≤0.002A(200 to 1090 nm)
Grating 1200 lines/mm
Drifting ≤0.0009 Abs/30 min (250 nm and 500 nm after 2h warm-up)
Dimensions(W×D×H) 74×63×45 Cm
Weight 35    Kg
Features
  • The blazed hologram gratings are used in the dual-beam UV VIS Spectrophotometer
  • Designed with an 8-inch color touch screen, advanced user interface, powerful functions, and simple operation
  • The equipment performs well in qualitative and quantitative testing due to its powerful functions, such as
  • Examine the entire spectrum
  • Linear regression analysis
  • Extensive frequency searching
  • Direct reading with concentration
  • Persistence of time-based kinetics
  • Measurement of multiple wavelengths
  • A sophisticated power protection system is built into the equipment
  • It has a large internal memory and can hold test results, image data, regression analysis, and correction data. As a result, when turned on, it performs a quick initialization
  • Connected with printer, which can print results or draw curves from spectral scanning, fixed wavelength time-based scanning, and linear repression
  •  The device can be connected to a PC via a USB, which not only improves performance in data testing and spectrum scanning but also expands the memory to save more testing results
  • Spectrum Bandwidth : 2 nm
  • Wavelength Range : 190 to 1100 nm
  • Monochromatic Type : Czerny-Turner
$1,665.00
  • Spectrum Bandwidth : 0.5 nm, 1nm, 2 nm, 4 nm, 5 nm
  • Wavelength Range : 190 to 1100 nm
  • Monochromatic Type : Czerny-Turner
$1,573.00
  • Monochromatic type : Czerny turner
  • Focal length : 160 mm
  • Wavelength Range : 190 to 1100 nm
$1,906.00

  • Wavelength Range : 190 to 900 nm
  • Wavelength Accuracy : £ ±0.5 nm
  • Wavelength Repeatability : £ 0.3 nm (single direction)
$1,980.00
  • Wavelength range  : 190 to 900 nm
  • Spectral bandwidth : 0.1, 0.2, 0.4, 1.0 and 2.0 nm
  • Accuracy of the wavelength : ±0.15 nm
$1,536.00
  • Wavelength Range : 190 to 850 nm
  • Wavelength Accuracy : ± 1 nm
  • Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
$1,922.00
  • Wavelength Range : 190 to 850 nm
  • Wavelength Accuracy : ± 1nm
  • Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
$1,329.00
  • Light Path : 1mm
  • sample Volume : 1 to 2μL
  • Detection Range : 190 to 850 nm
$1,963.00
  • Optical Path : 1/0.5/0.05 mm automatic conversion
  • Optical Range : 190 to 1100 nm
  • Sample Volume : 0.3 to 2.0 μl
$1,334.00
  • Analysis Principle : Energy-dispersive X-ray fluorescence analysis
  • Element Measuring Range : Any element from Na(11)-U(92)
  • Minimum Measuring Limit : Cd/Hg/Br/Cr/Pb≤2 ppm
$1,537.00
  • Exciting Optical Filters : Interface optical filter (10 nm bandwidth)
  • Wavelength : 365 nm
  • Emission Monochromatic : C-T diffraction grating (EM 200 to 900 nm )
$1,066.00

Single Beam UV VIS Spectrophotometer

Single Beam UV-Visible Spectrophotometers are designed for accurate measurement of light absorbance and transmittance. They provide a wide wavelength range, covering the UV and visible spectrum for diverse applications. These units include automatic wavelength adjustment, ensuring precise and consistent wavelength selection. Our Spectrophotometers retain data after power loss, ensuring secure results. They provide USB and printer connectivity, allowing easy data transfer and efficient reporting.

  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
$1,586.00
  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
$1,799.00
  • Photometry : Split Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
$1,913.00
  • Photometry : Split Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
$1,170.00
  • Photometry : Single beam
  • Monochromatic Type : Littrow
  • Focal Length : 160 mm
$1,186.00